...

How to Flash ElphaPex DG1+ Firmware and Where to Download It

ElphaPex DG1+ firmware update

Download DG1+ firmware from the official ElphaPex Firmware and Tools Download page. Select a package explicitly identified for the ElphaPex DG1+ and verify its model and version before installing it.

For a DG1+ that is operating normally, the easiest method is to upload the firmware through the miner’s web dashboard. ElphaPexTool can update one or multiple miners, while an SD card should normally be used when dashboard and tool-based upgrades fail.

Do not install DG1 firmware on a DG1+. Although the two miners belong to the same product family and may use similar control-board hardware, they require different firmware. Installing an incompatible image can prevent the miner from booting, detecting its hashboards or operating correctly.

Where to Download Official DG1+ Firmware

Firmware controls the DG1+ control board, hashboards, fans, temperature protection, networking and mining processes. Only download it from a source that can verify the exact model.

ElphaPex Firmware and Tools Download Page

The primary download source is the official ElphaPex support center. Open Firmware/Tools Download and select the applicable product model.

Depending on the required upgrade method, download:

  • The latest DG1+ firmware
  • ElphaPexTool for network discovery and batch upgrades
  • ElphaPex_SDDiskTool for preparing a recovery card
  • The DG1/DG1+ firmware-upgrade instructions

The official download page may use a model filter or dynamic table that does not appear until a device type is selected. Search for “DG1+” rather than downloading the first file containing “DG1.”

If no DG1+ firmware appears, contact ElphaPex after-sales support or the original supplier. Do not substitute a DG1, DG Home 1 or DG2 image.

How to Confirm the File Supports the DG1+

Before opening or uploading a firmware package, confirm:

  • Model name: DG1+
  • Control-board compatibility
  • Firmware version
  • Release date
  • File extension
  • Upgrade method
  • Whether configuration can be retained
  • Download source

Compare the new version with the version displayed at the bottom of the DG1+ dashboard. The manual gives DG1+_SW_V1.0.2 as an example of a DG1+ firmware identifier.

A newer upload date does not automatically make a package compatible. Model identification is more important than the date.

Avoid renaming a DG1 file to make it appear compatible with the DG1+. Changing a filename does not modify the image’s internal hardware support.

Why DG1 and DG1+ Firmware Cannot Be Interchanged

The DG1 and DG1+ use different performance configurations and firmware. JSBIT’s DG1/DG1+ control-board information specifically warns that the two models require different firmware on the control board.

Incorrect firmware can cause:

  • Failure to boot
  • Zero hashrate
  • Missing hashboards
  • Incorrect fan behavior
  • Invalid temperature readings
  • Dashboard errors
  • Repeated restarts
  • Failed future upgrades

If the exterior label is unclear, check the dashboard, serial number, purchase record and hardware specification before downloading anything.

What to Prepare Before Flashing the DG1+

A normal firmware update is straightforward, but interrupted power or an incompatible file can make the control board inaccessible.

Record Pool, Network and Login Settings

Before flashing, record:

  • Pool 1, Pool 2 and Pool 3 addresses
  • Worker names
  • Pool passwords
  • Current IP address
  • Static-IP configuration
  • Subnet mask
  • Gateway
  • DNS server
  • Dashboard username and password
  • Current firmware version

Take screenshots of the Miner, Network and Dashboard pages. Even when an upgrade method offers to retain settings, keeping a separate record makes recovery easier.

The factory-default DG1+ dashboard credentials are:

  • Username: root
  • Password: root

Your existing password may remain after a normal upgrade. A recovery image or configuration-erasing operation may restore default credentials.

Check the Current Firmware and Control Board Version

Open the DG1+ dashboard and check the firmware version shown near the bottom of the interface.

Do not update simply because a file has a higher number. Read the release information to determine whether the update fixes a relevant problem, supports the installed hardware or is required by ElphaPex.

Also confirm that the machine is actually a DG1+. Common DG-series models include:

Model Typical identifier Firmware compatibility
DG1 DG1 Use DG1 firmware only
DG1+ DG1+ Use DG1+ firmware only
DG Home 1 DG Home 1 Not compatible
DG2 DG2 Not compatible

If a control board has previously been replaced, ask the seller or technician whether it was programmed for the DG1+.

Maintain Stable Power and Network Connections

The DG1+ uses two power inputs. Both must remain securely connected throughout an ordinary firmware upgrade.

Before beginning:

  • Check both power cables
  • Use stable 200–240V power
  • Avoid upgrading during storms or planned maintenance
  • Connect the miner through Ethernet
  • Keep the computer on the same local network
  • Prevent the computer from sleeping
  • Close unnecessary browser tabs and network tools
  • Do not restart the router

Never turn off the DG1+ because the web page temporarily stops responding during an upgrade. Temporary disconnection is expected while the control board writes the firmware and reboots.

How to Update DG1+ Firmware From the Web Dashboard

ElphaPex DG1+ web dashboard firmware update

The web interface is the preferred method for updating one DG1+ that still boots and allows normal dashboard access.

Find the Miner’s IP Address and Log In

Use ElphaPexTool or your router’s connected-device list to identify the miner.

With ElphaPexTool:

  • Connect the Windows computer and DG1+ to the same router.
  • Confirm that DHCP is enabled.
  • Open ElphaPexTool.
  • Select the plus button and add the local IP range.
  • Select Scan.
  • Double-click the DG1+ entry.
  • Log in through the browser.

Use your current credentials. If the password has never been changed, try root for both the username and password.

Upload the Correct .img or .zip Firmware File

The DG1+ manual states that the web interface supports .img and .zip firmware files.

To begin the update:

  • Open the miner’s web dashboard.
  • Select Update.
  • Select the firmware-file field or upload button.
  • Browse to the downloaded DG1+ firmware.
  • Check the filename again.
  • Confirm that it is intended for the DG1+.
  • Select UPDATE.

Do not extract a .zip package unless the instructions supplied with that specific release tell you to do so. The dashboard can support both formats, but the selected file must match the upgrade method.

After starting, the interface may display a message such as “Upgrading in process.” Do not close the browser, change settings or disconnect either power input.

Wait for the Upgrade and Automatic Reboot

The firmware instructions estimate approximately three minutes for a dashboard upgrade and reboot. Actual time can vary.

After waiting:

  • Refresh the dashboard.
  • Rescan the network if the old IP does not respond.
  • Log in again.
  • Find the installed firmware version.
  • Compare it with the uploaded version.

The update is complete only when the dashboard shows the intended firmware and the miner returns to normal operation.

How to Update Multiple DG1+ Miners With ElphaPexTool

ElphaPex DG1+ batch firmware management

ElphaPexTool is useful when several compatible DG1+ miners require the same firmware.

Scan and Select the Correct Miners

Open ElphaPexTool, add the applicable IP range and scan the network. Review the detected model and IP address before selecting any units.

Do not include a DG1, DG Home 1 or another model in a DG1+ batch update.

Select the Firmware and Retention Option

Select Upgrade, choose the correct miner type and browse to the DG1+ firmware file.

The tool may provide:

  • Upgrade selected
  • Upgrade all
  • Retain settings after upgrade

Use Upgrade selected unless every listed device has been verified as the same compatible model.

Enable Retain settings after upgrade if you want the tool to preserve the existing pool and network configuration. You should still keep a separate backup of those settings.

Confirm Every Miner After the Upgrade

The ElphaPex instructions estimate one to two minutes for the initial tool process and approximately five minutes for the DG1/DG1+ to upgrade and restart.

A success message from the tool is useful, but it is not the final verification. Reopen each miner and confirm:

  • Correct firmware version
  • Correct pool settings
  • All hashboards detected
  • Normal temperatures
  • Normal fan operation
  • Stable pool-side hashrate

How to Recover DG1+ Firmware With an SD Card

ElphaPex DG1+ SD card firmware recovery

Use SD card recovery when the dashboard update and ElphaPexTool methods fail, or when the control board cannot complete a normal firmware upgrade.

This is a recovery procedure rather than the first update method.

When an SD Card Recovery Is Necessary

An SD card may be appropriate when:

  • The web dashboard cannot upload firmware
  • ElphaPexTool reports repeated update failure
  • The miner cannot finish booting
  • The existing firmware appears corrupted
  • ElphaPex support recommends recovery
  • A previous upgrade was interrupted

SD recovery will not repair physically damaged storage, hashboards, fans, power supplies or control-board components.

Prepare the Card With the Official Recovery Image

You need:

  • A Windows computer
  • An SD card with at least 4GB capacity
  • ElphaPex_SDDiskTool
  • The correct DG1+ recovery firmware

If the firmware was downloaded as a compressed package, extract it to obtain the required update.img file.

Then:

  • Insert the SD card into the computer.
  • Open ElphaPex_SDDiskTool.
  • Select the correct removable disk.
  • Confirm that the selected disk is the SD card.
  • Under function mode, select only Upgrade Firmware.
  • Use the Firmware button to choose update.img.
  • Select Create.
  • Wait for the success message.

Card creation overwrites the selected removable disk. Verify the drive carefully to avoid erasing another storage device.

After successful creation, the root directory of the SD card should contain two files. The tool renames the firmware image from update.img to sdupdate.img.

Do not manually copy an ordinary web-upgrade package to an empty card and assume that it is bootable. Use ElphaPex_SDDiskTool as specified.

Boot the DG1+ and Complete the Recovery Process

After preparing the card:

  • Power off the DG1+ completely.
  • Disconnect both power inputs.
  • Insert the prepared SD card into the miner.
  • Reconnect both power inputs.
  • Power on the DG1+.
  • Wait approximately five minutes.
  • Watch the control-board indicator lights.

According to the firmware-upgrade instructions, slowly flashing red and green LEDs indicate that the upgrade has completed successfully.

Once the success pattern appears:

  • Remove the SD card.
  • Allow the device to restart automatically.
  • Wait for normal startup.
  • Scan the network for the DG1+.
  • Verify the installed firmware.

Do not remove the SD card or disconnect power while the upgrade is still running. If the expected LED pattern does not appear, record the actual pattern and contact support rather than repeating the process with unrelated images.

How to Configure the DG1+ After Flashing

A successful firmware installation is only the first part of the process. The miner must also reconnect to the network and mining pool.

Find the Miner’s IP Address Again

The previous IP may remain valid when settings were retained. If it does not respond, run another ElphaPexTool scan or check the router’s DHCP client list.

Confirm that:

  • Ethernet activity lights are present
  • The miner and computer are on the same subnet
  • DHCP is enabled
  • The router is not using client isolation
  • The computer firewall permits local discovery

Do not assume the firmware failed only because the old IP address changed.

Restore Pool, Worker and Network Settings

Open the Miner section and configure:

  • Pool 1 address
  • Pool 1 worker name
  • Pool 1 password
  • Pools 2 and 3 as backups

Select SAVE and confirm that the miner connects to the primary pool.

If required, restore the static IP, subnet mask, gateway and DNS configuration. Verify each entry before saving because an incorrect gateway or subnet can make the dashboard inaccessible again.

Change the dashboard password if it returned to root.

Verify Hashrate, Temperature and Fan Operation

Allow the DG1+ to initialize before evaluating performance. Then check:

  • Chip count
  • Individual hashboard status
  • Theoretical hashrate
  • Actual miner hashrate
  • Pool-side accepted hashrate
  • Inlet and outlet temperatures
  • Fan behavior
  • Rejected shares
  • Unexpected restarts

Do not manually change fan speed to compensate for a firmware problem. The DG1+ normally adjusts fan speed according to operating temperature.

DG1+ Firmware Upgrade Troubleshooting

Use the symptoms after an unsuccessful update to decide whether to retry, perform SD recovery or request technical support.

Problem What to check
Dashboard rejects file Model, format, corruption and firmware source
Upgrade remains at zero Browser, network and file selection
Miner disappears temporarily Allow reboot time and rescan
Miner never returns Ethernet, DHCP, power and SD recovery
Zero hashrate Pool settings, hashboards and firmware model
Missing boards Wrong firmware or hardware connection
Repeated restarting Power, temperature, image or control board
Wrong version displayed Upload failed or old package was selected

Firmware File Is Rejected by the Dashboard

A rejected package commonly indicates:

  • Incorrect model
  • Unsupported file format
  • Incomplete download
  • Corrupted archive
  • File modified or renamed
  • Firmware older than permitted
  • Browser upload failure

Download the firmware again from ElphaPex and compare the filename and release information. Do not bypass model validation or force an incompatible file.

Miner Does Not Reboot or Appear on the Network

Wait at least five minutes before troubleshooting. Then:

  • Rescan with ElphaPexTool
  • Check the router client list
  • Test the Ethernet cable
  • Confirm both power inputs
  • Try another router port
  • Check indicator lights
  • Perform one controlled power cycle

If it still does not appear, prepare the correct SD recovery card or contact ElphaPex support.

Zero Hashrate or Missing Hashboards After Flashing

First confirm that the pool configuration is correct. If the dashboard detects fewer boards or chips than before the update, stop and check the firmware identity.

Do not repeatedly reflash random versions. Save screenshots and provide the following to support:

  • Miner serial number
  • Exact model
  • Previous firmware
  • Installed firmware
  • Control-board version
  • LED behavior
  • Dashboard errors
  • Number of detected hashboards

DG1+ Firmware Safety and Warranty Warnings

Firmware changes can affect stability and warranty eligibility. Treat every update as a controlled maintenance task.

Avoid Third-Party and Modified Firmware

Modified firmware may promise higher hashrate or lower power, but it can introduce:

  • Hidden developer fees
  • Unauthorized remote access
  • Malware
  • Incorrect voltage settings
  • Thermal-protection changes
  • Pool redirection
  • Warranty problems

Use official firmware unless the risks of a third-party image have been independently evaluated and accepted.

Never Interrupt Power During an Upgrade

Power loss while the control board is writing its system image can corrupt the installed firmware. Maintain both DG1+ power connections until the update is complete.

Do not upgrade during unstable power conditions. For a mining farm, consider whether the control board and network equipment can be supported by appropriate backup power.

When to Contact ElphaPex Technical Support

Contact support when:

  • The correct firmware is not listed
  • The hardware revision is uncertain
  • The miner cannot boot
  • SD recovery repeatedly fails
  • LED behavior does not match the instructions
  • Hashboards disappeared after flashing
  • The control board may be damaged
  • You need to downgrade firmware

The JSBIT user-manual library also provides the DG1+ server manual and firmware-upgrade instructions.

Conclusion: How to Flash DG1+ Firmware Safely

Download DG1+ firmware from ElphaPex’s official support page and verify that the package explicitly supports the DG1+. Never substitute firmware from the DG1, DG Home 1 or DG2.

Use the web dashboard for a normal individual upgrade. Use ElphaPexTool when updating multiple verified DG1+ miners, and use an SD card only when normal upgrade methods fail.

During every method, maintain stable power, avoid unrelated operations and wait for the miner to restart. After flashing, confirm the installed version, restore pool settings if necessary and monitor hashboards, temperature, fans and pool-side hashrate.

DG1+ Firmware FAQs

What File Format Does the DG1+ Support?

The DG1+ web dashboard supports .img and .zip firmware packages. SD card recovery requires the appropriate update.img, which ElphaPex_SDDiskTool prepares as sdupdate.img.

Does a Firmware Update Delete Pool Settings?

A firmware update may retain pool settings, particularly when Retain settings after upgrade is selected in ElphaPexTool. Always record the configuration because recovery images or some upgrade packages may erase it.

Can I Install DG1 Firmware on a DG1+?

No. DG1 firmware should not be installed on a DG1+. The models require different firmware even when their control boards appear similar.

How Long Does a DG1+ Firmware Update Take?

A dashboard upgrade normally takes approximately three minutes, while ElphaPexTool or SD card procedures may require around five minutes plus reboot time. Do not interrupt power if the process takes longer.

Can I Downgrade the DG1+ Firmware?

A downgrade may be possible only when the target package supports the exact DG1+ hardware and the manufacturer permits it. Contact ElphaPex support before downgrading because older firmware may be blocked or incompatible.

Where Can I Download ElphaPexTool and ElphaPex_SDDiskTool?

Download both utilities from the official ElphaPex Firmware/Tools Download section. Avoid third-party file-sharing links because the utilities can modify firmware and removable storage.

Reading next

Learn how to restart or factory reset an ElphaPex DG1+, restore its default login, find its IP address, reconfigure mining pools, and troubleshoot reset problems.

Is the Antminer S19k Pro still profitable in 2026? Review its hashrate, power cost, break-even electricity rate, used-miner risks, installation requirements, and upgrade options.