How to Reset an ElphaPex DG1+ Miner

Reset ElphaPex DG1+ miner safely

To factory reset an ElphaPex DG1+, log in to its web dashboard, locate the RESTORE option, and confirm the restore operation. According to the DG1+ Server Manual, restoring the initial settings clears the mining-pool configuration and returns the dashboard password to its original value.

The default DG1+ dashboard credentials are:

  • Username: root
  • Password: root

A factory reset is not always necessary. If the miner is temporarily offline, reporting an unstable hashrate, or failing to connect to a pool, begin with a normal restart. Use a factory reset when incorrect network or pool settings cannot be corrected, the login configuration is causing problems, or ordinary troubleshooting has failed.

This guide is based on the DG1+ Server Manual V1.0.2. Menu names may change slightly with firmware updates, so use the current manual for your installed firmware whenever possible.

When Should You Reset the DG1+?

Resetting can resolve configuration problems, but it will not repair a failed fan, power supply, control board, hashboard, temperature sensor, or network cable.

Identify the likely cause before erasing the miner’s settings.

Network, Pool and Login Problems

A factory reset may be appropriate when:

  • You cannot remember the dashboard password
  • The miner contains incorrect pool information
  • A previous owner’s pool accounts remain configured
  • Static network settings prevent access
  • The dashboard loads but settings cannot be corrected
  • The miner was configured for a different network
  • A configuration error appeared after a firmware change

Do not reset the miner simply because the pool-side hashrate fluctuates for a few minutes. Pool hashrate naturally changes as shares are submitted. Confirm the problem over a longer period and inspect the dashboard first.

Firmware Errors and Unstable Hashrate

A reset may help if unstable performance began after configuration changes. It is less likely to solve a physical hardware problem.

Before resetting, check:

  • Whether all hashboards are detected
  • Inlet and outlet temperatures
  • Chip status
  • Fan operation
  • Pool connection status
  • Rejected shares
  • Ethernet connection
  • Power stability
  • Miner logs

The DG1+ manual states that mining stops when the outlet temperature reaches 85°C and high-temperature protection activates. A miner stopping because of excessive heat requires better airflow or hardware maintenance, not repeated factory resets.

Reboot vs. Factory Reset

A reboot restarts the operating system without intentionally erasing the mining configuration. A factory reset restores initial settings and removes user configuration.

Action Pool settings Login password When to use
Dashboard reboot Normally retained Retained Temporary software or connection problem
Safe power cycle Normally retained Retained Dashboard is unavailable or miner is frozen
RESTORE operation Cleared Restored to original password Lost password or serious configuration problem
Firmware recovery May be cleared May return to default Corrupted or unbootable system

Always try the least disruptive option first. A restart is normally preferable when you can still access the dashboard and the configuration is correct.

What to Prepare Before Resetting the DG1+

A reset takes only a short time, but reconfiguration becomes much easier when essential information is recorded first.

Back Up Pool and Network Settings

Take screenshots or write down:

  • Primary pool URL
  • Backup pool URLs
  • Worker name
  • Pool password
  • Payout account or subaccount
  • Current IP address
  • Subnet mask
  • Gateway
  • DNS server
  • Firmware version

The DG1+ can store three mining pools. Pool 1 has the highest priority, followed by pools 2 and 3. Record all three configurations before selecting RESTORE.

Do not confuse the pool worker name with a wallet address. Some pools use a wallet-based worker format, while others require a registered account and worker ID.

Confirm the Miner’s IP Address and Login Details

If the dashboard is still accessible, note its IP address before resetting. You can normally find the miner through your router’s connected-device page or ElphaPexTool.

The DG1+ manual describes the following discovery process:

  • Download ElphaPexTool from an authorized ElphaPex source.
  • Extract the downloaded package.
  • Open ElphaPexTool.exe on a Windows computer.
  • Add the appropriate local network range.
  • Select Scan.
  • Double-click the identified miner to open its dashboard.

ElphaPexTool is listed as Windows-only in the manual. The computer and miner should be connected to the same local network during discovery.

Check Power and Ethernet Connections

The DG1+ uses two power inputs. The manual specifies that both power cables must be connected at the same time and that all power inputs must be disconnected when powering down the machine.

Before performing a reset, confirm:

  • Both power cables are secure
  • The input voltage is within 200–240V
  • The circuit can support the continuous load
  • The Ethernet cable is connected
  • Router activity lights are visible
  • The miner has completed its startup sequence
  • Fans are operating normally

An intermittent power or Ethernet connection can resemble a configuration failure. Correct those issues before restoring factory settings.

How to Restart the DG1+ Without Erasing Settings

ElphaPex DG1+ miner restart and control panel

Use a restart when the miner is slow, temporarily disconnected from the pool, or displaying an unusual dashboard status but its settings remain correct.

Rebooting Through the Miner Dashboard

If your installed firmware provides a restart or reboot option:

  • Open the DG1+ IP address in a browser.
  • Log in to the dashboard.
  • Locate the system-management or restart option.
  • Select Reboot or Restart.
  • Wait for the machine to complete its startup process.
  • Scan the network again if the dashboard does not reopen automatically.

Do not select RESTORE when you only want to restart. RESTORE clears the configured pools and resets the password.

Because interface options can differ between firmware releases, follow the labels displayed by your installed version. The V1.0.2 manual documents the RESTORE operation but does not describe a separate dashboard reboot procedure.

Performing a Safe Power Cycle

If the dashboard is unavailable, perform a controlled power cycle:

  • Record the current symptoms.
  • Disconnect both DG1+ power inputs.
  • Wait until all fans and indicator lights stop.
  • Leave the miner disconnected for approximately one minute.
  • Check the power plugs and Ethernet cable.
  • Reconnect both power inputs correctly.
  • Allow the miner to boot without interruption.
  • Use ElphaPexTool or the router to find it again.

Do not repeatedly connect and disconnect power within a few seconds. Rapid cycling can place unnecessary stress on the power supply and control board.

Checking the Miner After Restart

After the miner returns online, verify:

  • All hashboards are detected
  • Pool status is connected
  • Hashrate begins increasing
  • Temperatures remain normal
  • Fans adjust automatically
  • No abnormal chip status appears
  • Pool-side accepted hashrate develops over time

Do not evaluate pool performance immediately after startup. Allow sufficient time for the miner to submit shares and establish a meaningful average.

How to Factory Reset the DG1+ From the Dashboard

The documented DG1+ factory-reset method uses the RESTORE option in the web interface.

Accessing the System or Administration Menu

First, locate the miner on the network:

  • Run ElphaPexTool on a Windows computer connected to the same network.
  • Scan the applicable IP range.
  • Double-click the DG1+ entry.
  • Log in with your current username and password.
  • Locate RESTORE in the web interface.

If the password has already been lost and the dashboard cannot be accessed, skip to the troubleshooting section. The manual’s RESTORE procedure assumes that you can enter the web interface.

Restoring the Default Configuration

Before continuing, confirm that the pool settings have been recorded.

Then:

  • Click RESTORE.
  • Confirm the operation if the interface displays a confirmation prompt.
  • Do not disconnect power during the restoration process.
  • Wait for the miner to complete the operation and restart.
  • Scan for the miner again.

The manual specifically warns that RESTORE clears the pool settings and restores the original password. After restoration, try:

  • Username: root
  • Password: root

Change the password after regaining access.

Waiting for the Reset and Reboot to Finish

Do not interrupt the miner while it is restoring settings. The dashboard may temporarily become unavailable, and its network address may need to be rediscovered.

There is no universal completion time documented in the manual. Allow several minutes for the control board and mining process to restart before treating the reset as unsuccessful.

If the miner does not reappear:

  • Rescan the local network
  • Check the router’s client list
  • Confirm Ethernet activity
  • Verify that both power inputs are connected
  • Restart ElphaPexTool
  • Check whether the computer and miner remain on the same subnet

How to Reset the DG1+ With the Physical Button

The DG1+ Server Manual V1.0.2 does not document a physical-button factory-reset procedure. For that reason, the dashboard RESTORE option should be treated as the standard reset method.

Locating the Reset Button

Inspect the control panel labels before pressing anything. A button may be intended for IP identification, status reporting, recovery, or another function rather than factory restoration.

Do not assume that the DG1+ uses the same button sequence as an Antminer, Bitaxe, NerdQaxe or another ElphaPex model. Similar-looking controls can perform different operations.

Correct Button Timing and Indicator Lights

There is no verified universal button-hold duration for factory-resetting the DG1+ in the V1.0.2 manual. Avoid following instructions written for unrelated miners, such as holding a button for five or ten seconds during startup.

An incorrect procedure may:

  • Fail to reset the machine
  • Trigger a recovery mode
  • Interrupt the boot process
  • Make the miner temporarily inaccessible
  • Complicate technical support

Use physical controls only when the manufacturer or supplier provides instructions for your exact DG1+ hardware and control-board version.

What to Do if the Reset Button Does Not Work

If you cannot access the dashboard and no documented button procedure is available:

  • Confirm the miner has completed startup.
  • Replace or test the Ethernet cable.
  • Connect the miner and computer to the same router.
  • Scan all appropriate network segments.
  • Check the router’s DHCP client list.
  • Try the existing and default credentials.
  • Contact ElphaPex or the supplier with the serial number and firmware details.

The JSBIT DG1+ product page includes the appropriate manual and technical information for the model.

How to Configure the DG1+ After a Factory Reset

ElphaPex DG1+ network and mining pool configuration

A restored miner will not resume mining until valid pool information has been entered.

Finding the Miner’s New IP Address

Run ElphaPexTool and scan the local network. The miner may appear at a different address if its network configuration or DHCP lease changed.

If it does not appear, confirm:

  • The router’s DHCP service is active
  • No VLAN separates the miner and computer
  • The computer’s firewall is not blocking discovery
  • The Ethernet port and cable work
  • The scanned IP range matches the local subnet

You can also inspect the router’s device list for a newly connected Ethernet client.

Restoring Pool, Worker and Wallet Settings

Open the dashboard and log in with root as both the username and password.

Then:

  • Open the Miner section.
  • Enter the primary mining-pool address.
  • Enter the worker name or account ID.
  • Enter the pool password.
  • Configure pools 2 and 3 as backups.
  • Select SAVE.
  • Change the dashboard password.

Copy pool addresses from the pool’s official configuration page. A typing error in the hostname, port, worker name or password can prevent mining even when the DG1+ itself is operating normally.

Verifying Hashrate, Temperature and Fan Operation

Open the Dashboard and monitor:

  • Number of detected chips
  • Hashrate for each board
  • Theoretical hashrate
  • Inlet and outlet temperature
  • Chip operating status
  • Pool connection
  • Fan behavior

Do not manually force the fan speed without a specific technical reason. The DG1+ manual states that the server automatically adjusts its fan speed according to environmental temperature.

DG1+ Reset Troubleshooting

ElphaPex DG1+ reset troubleshooting

If the factory reset does not resolve the problem, use the symptoms to determine the next step.

Problem Likely checks
Miner not found Ethernet, router, subnet and DHCP
Default login rejected Browser cache, wrong IP or reset not completed
Pool remains disconnected Pool URL, port, worker and DNS
Hashrate remains zero Hashboards, temperature, firmware and pool status
Miner repeatedly restarts Power supply, voltage, overheating or hardware
Missing hashboard Signal cables, board fault or control board
Dashboard will not load IP conflict, network settings or control-board issue

Miner Not Appearing on the Network

Start with the physical network:

  • Test the Ethernet cable
  • Try another router port
  • Look for port activity lights
  • Disable Wi-Fi isolation or guest-network isolation
  • Confirm that the scanning computer is on the same network
  • Review the router’s connected clients

Do not keep restoring the miner if the problem is a damaged cable or incorrect subnet.

Dashboard Password Still Not Working

After a successful RESTORE operation, try root for both the username and password.

If that fails:

  • Confirm that you are opening the DG1+ rather than another miner
  • Clear the browser cache or use a private window
  • Try another browser
  • Repeat the network scan
  • Allow more time for restoration to finish
  • Perform one safe power cycle
  • Contact technical support

Avoid repeatedly guessing passwords because it does not address an incomplete reset or incorrect IP address.

When to Reinstall the Official DG1+ Firmware

Consider a firmware recovery only when normal restart, network troubleshooting and RESTORE have failed, or when the system is clearly corrupted.

The DG1+ supports .img and .zip firmware updates through the dashboard. Firmware must be intended specifically for the DG1+. The DG1 and DG1+ use different firmware even though their hardware families are related.

Before upgrading:

  • Confirm the exact model
  • Check the installed firmware version
  • Download the file from an authorized source
  • Maintain uninterrupted power
  • Do not perform other dashboard operations
  • Wait for the miner to reboot automatically

The JSBIT user-manual library provides the DG1+ manual and related ElphaPex documentation. If the control board no longer boots, obtain the correct recovery procedure from ElphaPex or technical support rather than installing firmware for another model.

Conclusion: Resetting the DG1+ Safely

The correct documented method for factory-resetting an ElphaPex DG1+ is to enter its web dashboard and select RESTORE. This clears the mining-pool settings and restores the original dashboard password.

After the reset, log in with root as the username and root as the password, re-enter all three pool configurations, change the password, and verify every hashboard, temperature reading and fan.

Use a normal restart or safe power cycle before performing a factory reset when the problem appears temporary. Because the DG1+ V1.0.2 manual does not document a physical-button reset sequence, do not copy button instructions from a different miner.

If the machine remains inaccessible after checking power, Ethernet, DHCP and credentials, contact support with its serial number, control-board version and firmware information.

ElphaPex DG1+ Reset FAQs

Does a Factory Reset Delete Pool Settings?

Yes. The DG1+ manual states that the RESTORE operation clears the mining-pool settings. Record all pool URLs, workers and passwords before resetting.

How Long Does a DG1+ Factory Reset Take?

A DG1+ reset and reboot should normally take several minutes, although the manual does not specify an exact duration. Do not disconnect either power cable while restoration is in progress.

What Is the Default DG1+ Login Password?

The default DG1+ username is root and the default password is root. Change the password after completing the reset and restoring access.

Can I Reset the DG1+ Without Internet Access?

Yes. The dashboard reset operates over the local network and does not require public internet access. The miner and computer must still be connected to the same local network.

Will Resetting the DG1+ Change Its Firmware Version?

No. Restoring the initial settings normally resets configuration data without changing the installed firmware version. A firmware upgrade or recovery is a separate operation.

Does the DG1+ Have a Physical Factory-Reset Button?

The DG1+ Server Manual V1.0.2 does not document a physical-button factory-reset procedure. Use the dashboard RESTORE function or obtain model-specific instructions from ElphaPex support.

Reading next

Learn where to download official ElphaPex DG1+ firmware and how to update it through the dashboard, ElphaPexTool or an SD card recovery process.

Is the Antminer S19k Pro still profitable in 2026? Review its hashrate, power cost, break-even electricity rate, used-miner risks, installation requirements, and upgrade options.